Last Modified: 11-29-2007 1.6 C
Service Category: Drivetrain Section: Automatic Transmission/Transaxle
Model Year: 2008 Model: Sequoia Doc ID: RM000000W8H03GX
Title: A750F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: DESCRIPTION (2008 Sequoia)

DTC

P0985

Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC

P0986

Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)

DESCRIPTION

Shifting from 1st to 5th is performed in combination with the "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2 and SR which is controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated smoothly. (In case of an open or short circuit, the ECM stops sending current to the circuit. For details, refer to the Fail-Safe Chart A750F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: FAIL-SAFE CHART (2008 Sequoia) .)

DTC No.

DTC Detection Condition

Trouble Area

P0985

ECM detects short in solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic)

  • Short in shift solenoid valve SR circuit
  • Shift solenoid valve SR
  • ECM

P0986

ECM detects open in solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic)

  • Open in shift solenoid valve SR circuit
  • Shift solenoid valve SR
  • ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve SR is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.

When the shift solenoid valve SR is off, if its resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve SR circuit A750F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: FAIL-SAFE CHART (2008 Sequoia) .

MONITOR STRATEGY

Related DTCs

P0985: Shift solenoid valve SR/Range check (Low resistance)

P0986: Shift solenoid valve SR/Range check (High resistance)

Required sensors/Components

Shift solenoid valve SR

Frequency of operation

Continuous

Duration

0.128 seconds or more

MIL operation

Immediately

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

All

The monitor will run whenever the following DTCs are not present

None

P0985: Range Check (Low Resistance)

Shift solenoid valve SR

ON

Battery voltage

8 V or more

Ignition switch

ON

Starter

OFF

P0986: Range Check (High Resistance)

Shift solenoid valve SR

OFF

Battery voltage

8 V or more

Ignition switch

ON

Starter

OFF

TYPICAL MALFUNCTION THRESHOLDS

P0985: Range Check (Low Resistance)

Shift solenoid valve SR resistance

8 Ω or less

P0986: Range Check (High Resistance)

Shift solenoid valve SR resistance

100 kΩ or more

COMPONENT OPERATING RANGE

Shift solenoid valve SR resistance

11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM



INSPECTION PROCEDURE

HINT:

The shift solenoid valve SR turns ON/OFF normally when the shift lever is in D.

ECM gear shift command

1st

2nd

3rd

4th

5th

Shift solenoid valve SR

OFF

OFF

OFF

OFF

ON

PROCEDURE

1.

INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)


(a) Disconnect the D41 transmission wire connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

7 (SR) - Body ground

20°C (68°F)

11 to 15 Ω

OK

2.

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


(a) Disconnect the D56 ECM connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

D56-6 (SR) - Body ground

20°C (68°F)

11 to 15 Ω

OK

3.

INSPECT SHIFT SOLENOID VALVE SR


(a) Remove the shift solenoid valve SR.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

Shift solenoid valve SR connector terminal - Shift solenoid valve SR body

20°C (68°F)

11 to 15 Ω

(c) Connect the battery positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.

OK